上海GM交流

Ventilation Industry Solutions

——R&D, production and sales

National hotline:

thirteen billion eight hundred and ninety-seven million nine hundred and sixty-six thousand two hundred and twenty-one

 Shenyang Ventilation Engineering

Installation environment of Shenyang ventilation project

2021-04-12 10:29:35
second

Shenyang Ventilation Engineering Installation environment for

The inner walkway without direct natural ventilation and with a length of more than 20m or with a length of more than 60m despite direct natural ventilation;


Rooms without windows on the ground or with fixed windows with an area of more than 100m2 and frequent people staying or more combustibles;


Atrium without natural smoke exhaust conditions or with a clearance height of more than 12m;


In addition to the rooms that use windows such as window wells for natural smoke exhaust, the total area of each room exceeds 200m2 or the area of one room exceeds 50m2, and there are often people staying or there are many combustibles in the basement.

 Shenyang smoke exhaust project

The ventilation and smoke exhaust pipe facilities set in high-rise buildings shall meet the following requirements:


(1) The smoke outlet shall be set on the ceiling or on the wall near the ceiling, and the horizontal distance from the adjacent edge of the nearby emergency exit along the aisle direction shall not be less than 1.50m. The distance from the smoke outlet on the ceiling to combustible components or combustibles shall not be less than 1.00 m.


The smoke outlet shall be closed at ordinary times, and shall be equipped with manual and automatic opening devices.  


(2) The horizontal distance between the smoke outlet in the smoke control zone and the remote point shall not exceed 30m.


The smoke exhaust branch pipe shall be equipped with smoke exhaust that can be automatically closed when the smoke temperature exceeds 280 ℃ Fire damper


(3) The smoke exhaust fan can be centrifugal fan or smoke exhaust fan Axial flow fan The entrance of the machine room shall be equipped with smoke fire damper which can automatically close when the flue gas temperature exceeds 280 ℃. The smoke exhaust fan shall be able to work continuously for 30min at 280 ℃.  


(4) In the mechanical smoke exhaust system, when any smoke outlet or smoke exhaust valve is opened, the smoke exhaust fan shall be able to start automatically.  


The content of this article comes from the Internet. If you have any questions, please contact us!


Recent browsing:

24-Hour Hour Hotline

thirteen billion eight hundred and ninety-seven million nine hundred and sixty-six thousand two hundred and twenty-one

Contact: Manager Li

Tel: 13897966221

Address: Shenyang Hunnan Xiangrui Industrial Park, No. 600, Nanling Village, Lixiang Street, Dongling District, Shenyang, Liaoning

WeChat QR code


Copyright @ Shenyang Hunnan Hongbaocheng Ventilation Equipment Factory Record No.: Service support: